NSLThermal Insulation
5mm thick

1000mm wide

25 metre rolls

10mm thick

1000mm wide

25 metre rolls

15mm thick

1000mm wide

25 metre rolls

1000mm wide

25 metre rolls


NSL Foil Insulation

The reflective barrier properties and heat reflectivity of aluminium foil are widely used in the construction of modern building and housing, adding to the insulation property's of modern buildings. Aluminium foil is also used as a skin laminated to closed cell foam for heat-insulating and incombustible materials to provide high performance insulation for pipework and ducting. The adhesive peal off backing is used to secure the NSL foil faced closed cell foam material. is also based on aluminium foil for its reflective surface, corrosion-resistance and long life.

Automotive Applications

In fire walls for vehicles and fire-proof doors and building panels, aluminium foil stops access to the oxygen required to support flames

Aluminium foil is also increasingly important in automotive components such as impact energy absorption structures and in catalytic converters. Favoured over steel because of better corrosion resistance and weight economy, special aluminium alloys provide the physical properties required in these aluminium foil applications.

NRP & NSL MATERIAL DATA SHEET

NRP & NSL Data file for Insulation        

  NRP & NSL    Insulation excellence

Thermal Insulation NRP and NSL Being a chemically cross-linked polyethylene foam provide excellent insulation.

see below Comparison table

2. No Moisture : A dense independent air cell is perfect with moisture as it can not penetrate the cell

3. Semi-Permanence : Chemically cross-linked polyethylene foam will last almost permanently without change due to it's excellent heat proof properties, cold-resistance & durability.

4. Flexibility, Anti-noise & vibration properties : both the closed and open cells protect from noise & vibration.

Example: 2mm provides a 21.8 db reduction

5. Fire retardant : It is very difficult to light & Releases no toxic smoke when in a fire

Both NRP and Neo have passed Australian Standards Test Method 1530 part 3 as listed below.

NRP & NSL Test AS/NZS 1530.3 - 1999

Simultanous determination of ignitability flame propagation, heat release and smoke release

Test Report MEAN

NRP. / NSL.

STANDARD ERROR

NRP. / NSL.

Ignition time
1.7 min
Nil
0.08
Nil
Flame propagation time
Nil s
Nil s
Nil
Nil
Heat release integral 17.6 kJ/m2 Nil. kJ/m2 0.5 Nil
Smoke release, log d -1.6630 -1.6836 0.0259 0.0419
Optical density. d
0.0219 /m
0.0212 /m

NRP & NSL Test AS/NZS 1530.3 - 1999

Simultanous determination of ignitability flame propagation, heat release and smoke release

Test Report NRP NSL Range
Spread of Flame Index 0 0 0 - 10
Heat Evolved Index 0 0 0 - 10
Smoke Developed Index 2 2 0 - 10

* A Various MTL Comparison Table

   Item

Density

( g/cm3)

Conductivity

( Kcal/mh'C )

Water Resistance

Aging

NSL & NRP

0.025

0.029

Excellent

Excellent

Styrofoam

0.030

0.031

Good

Good

Polystyrene foam

0.015

0.031

Good

Good

PU Foam

0.025

0.032

Bad

Bad

Glass Wool

0.01

0.034

Bad

Good

   Comparison of Insulation for Panel

Classify

"NSL & NRP"

Glass Wool

Styrofoam (EPS)

Physical Characters

Raw Material

Foaming no toxic polyethylene

Melting scrapped glass mixing with resin

Expanded polystyrene

Density ( g/cm3 )

0.029 ~ 35

0.024~32

0.015~20

Absorption ( g/cm3 )

0.01%

8%

0.8%

Thermal conductivity

( kcal/mhr'C at 20C )

0.029

0.042

0.076

Classify

NSL & NRP

Glass Wool

Styrofoam

Estimated life Cycle

15 years

5 years

10 years

General information

Insulation

Excellent &Stable

Excellent

Excellent

Heat Resistance

120C

400C

Below90c

Anti-condensation

Excellent

Problem

Dew in over-lap part

Water Proof

Excellent

Problem

*

Sound Absorption

Excellent

Good

No absorb internal sound

Anti-chemical

Strong

Strong

Poor/protected by panel

Anti-fungal

Strong

Weak

*

Shrinkage

None

Problem

None

Pollution/Toxic

None

Cancergenic

Toxic in fire

Inflammability

Non-flammability

 Fire Retardant

Fire Retardant

Flammable & Toxic

Flame protection

Good

Good

*

Construction

Economic Efficiency

Economic

Economic

*

Construction

Simple, no special clothing needed

Favorable in rainy season

Slightly complicated

Need skillful workers Coverings & dust masks needed

Special tool& equipment S/B supported on construction

Working Time

Shortest

Longer

Longer

Maintenance

Material is flexible/soft.

No serious damage could be occurred on construction but handle with care is needed

Damage could be occurred by careless construction.

High absorption of water.

Trouble with fungus

The glue could be melted in the sun or moisture.

Dew in over-lap part.

Rain leaks in worse case.

Repairing

Easy

Difficult

Difficult

Example of Thermal conductivity

The effect of "NSL & NRP" at 10mm is equal to glass wool at 25mm.

5mm PE foam is using at various places for roof/wall at factory, gymnasium, warehouse, farm, train-station, etc

General

 

Economic &Simple construction.

Excellent insulation.

Neat appearance.

No water absorbs ion.

Anti fungus/chemical

Long duration

 

Economic &slightly complicated construction.

Major Problems is high ratio of water-absorption..

Harmful for health.

*Cancergenic

High cost than life span.

Internal noise could be amplified by inside panel.

Styrofoam can be affected by moisture or uv rays

 NSL   Duct insulation excellence

1.       Shock absorption

2.       Excellent insulation

3.       Easy & Convenient for Processing & installation

4.       Strong in Chemicals, Temperature extremes & Ageing

5.      Excellent Flexibility & Durability

* Basic Specification

    Item

Thick

(mm)

Density

( g/cm3)

Tensile

( kg/cm2)

Thermal conductivity

( kcal/mh'C)

Safety

Temp.

( g/cm2)

Flexibility

Figure.

5 to 25

0.029

3.4

0.026~29

-100c ~ 80C

Good

     High Temp. Duct Insulation

1.       Fit for use at high temperature ( 170'C )

2.       Strong resistance for Acid.

3.       Good for Shock Absorption.

4.       Superior to Heat-Proof.

5.       Simple working process.